1) High EER and COP values
V5 X Series achieves the industry’s top class energy efficiency of cooling and heating by utilizing DC compressor control, DC Fan motor, and improved performance heat exchanger.
2) Large capacity for big sized building
The outdoor units capacity range from 8HP up to 88HP in 2HP increment, max. combination of 4 basic models.
3) Long piping length
The solution supports an incredible piping length of 1,000m (3280ft.) and level difference of 110m (360.8ft.), making it perfect for large projects.
4) High external static pressure
The high-static pressure propeller and optimized fan guard can adapt to various installation environments. Midea now offers up to 40Pa(0.16”W.G.) external static pressure units for customized applications. A standard 0-20Pa(0-0.08”W.G.) function is equipped by default.
5) Wide operation range
6) Duty cycling
In one combination, any outdoor unit can run as the master outdoor unit to equalize the service life of all units.
7) Back-up function
In a multiple system, when the master unit failed, any single unit can be set as the master unit,then the remaining units can keep on working. This can be set on PCB by DIP switches at site.
8) Quick warm-up and cool-down design
By utilizing the benefits of all DC inverter compressors, the system can reach full load quickly and shorten the warm-up and cool-down times to provide an immediate and comfortable air solution. Less temperature fluctuation will create a better living environment.
9) Intelligent defrosting technology
Intelligent defrosting program will judge the defrosting time according to the system real requirement, reduce the heating loss by unnecessary defrosting and make the indoor side more comfortable.
10) Outdoor unit night silent mode
Midea’s Night Silent Mode feature which is easily set on the PCB board allows the unit to be set to varies time options during Non-peak and Peak operation time optimizing the units noise output. Extra silent operation mode can reduce sound level further, minimum 43dB (A). Night silent operation will be activated X hours after the peak temperature during daytime, and it will go back to normal operation after Y hours.
11) Line Up
Capacity |
8HP |
10HP |
12HP |
14HP |
16HP |
V5 X Series |
MV5-X252W/V2GN1 | MV5-X280W/V2GN1 | MV5-X335W/V2GN1 | MV5-X400W/V2GN1 | MV5-X450W/V2GN1 |
Basic model |
![]() |
![]() |
![]() |
![]() |
![]() |
Capacity |
18HP |
20HP |
22HP |
||
V5 X Series |
MV5-X500W/V2GN1 | MV5-X560W/V2GN1 | MV5-X615W/V2GN1 | ||
Basic model |
![]() |
![]() |
![]() |